BM_Read

Description

The function FC BM_READ can be used to read a parameter by demand data communication of a bmaXX controller

 

Parameter Input

Data Type

Description

Req

BOOL

TRUE= Start to read parameter

FALSE= End to read a parameter

Index

INT

Parameter Index

Subindes

BYTE

Parameter Subindex

Len

BYTE

Parameter Type value

 

 

Parameter Output

Data Type

Description

Done

BOOL

Reading done without errors

Busy

BOOL

Read status is still active

Errror

BOOL

Parameter read error; ErrorID is valid

Value

DWORD

Parameter value

DataLen

BYTE

Total data length

ErrorID

DWORD

Communication ErrorID Siemens error list

 

Parameter

Input and output

Data Type

Description

Axis

UDT

BM Motion Control axis variable

 

Notes:

A command from "BM_Read" must not be activated before a command from another function block has been not successfully executed.

If an error occurs during the command execution, the error must be reset with "BM_Reset". Function block command will be executed successfully at "BM" .AXIS [x] .DRIVE.BM_AXIS_STATUS.ParmRW_Active = 0.

 

Input Req

TRUE at parameter input REQ starts the communication.

Input Index

The parameter index number to be read.

Input Subindex

The parameter sub-index number to be read.

LEN

The value of the parameter data type to be read

LEN

Data Type

Description of byte length

0x0001

BOOL

1

0x0002

SINT

1

0x0003

INT

2

0x0004

DINT

4

0x0005

USINT

1

0x0006

UINT or WORD

2

0x0007

UDINT or DWORD

4

0x0008

FLOAT

4

 

 

Output Done:

TRUE: Reading the parameter without errors if finished

FALSE: Not active

Output Busy:

TRUE: Reading status still active.

FALSE: Not active.

Output Error:

TRUE: There is an error at the service data communication for the parameter Read. Information at ErrorID is valid and error information refer to S7 Description

FALSE: No error active.

Output Value:

Parameter value to be read

Output Len:

Total data length of service data communication

Output ErrorID:

The information of Service Communication error (for details refer to S7 Description)

 

Input and output Axis:

UDT type symbolic BM Motion Control axis variable.

During the programming with the template data module DB5 (symbolic "BM") the following symbol text must be used: "BM".AXIS[x] (x is the drive axis number).

 

 