b maXX 4400 – Modular servo-controllers
Power units with five cooling variants and seven sizes
The b maXX 4000 has up to eleven slots for plug-in modules and can therefore be customized for special automation tasks. Special plug-in modules connect the b maXX 4000, for example, to all common bus systems. The plug-in module b maXX-drivePLC makes the drive intelligent.
The b maXX 4400 converter family
b maXX 4400 offers a power range from 1.1 to 315 kW. Rectifiers, intermediate circuit capacities and inverters are integrated in all devices.
b maXX-drivePLC -
One of the world's fastest drive-based PLCs
Function and option modules for b maXX 4400
With over 30 different function and option modules, b maXX can be easily adapted to the individual tasks of the automation and drive solution. The individual modules are designed as plug-in cards, so the drive controller no longer needs to be ordered pre-assembled. The machine builder can use various plug-in cards, function and option modules for b maXX 4400 to ensure a wide range of functions and plug in the required combinations himself. This way he can react quickly and flexibly to new requirements. In addition, this system guarantees quick extension of the drive at the user's premises. Production adjustments can be made in a short time and with a small extent of work.
Fieldbus systems
b maXX 4000 – The modular servo-controller
Braking energy
The control of a brake resistor is integrated in the device as a brake chopper. A ballast resistor is connected externally. On the one hand, this ensures optimum dimensioning and, on the other, reduces the construction volume of the control cabinet.
Mains filters
To ensure a cost-effective configuration, mains filters are always connected externally upstream of the device. This way, several power modules can be combined on one mains filter, which reduces the costs for the entire system.
Temperature-dependent fan control
The fan is open-loop controlled as a function of the internal temperature of the device. This lowers the overall energy balance, thus reducing the overall costs of a system.
DC link coupling
A DC link coupling of several power modules for energy compensation is possible. The excess energy is not “burned up”, but is available to other drive units without additional energy being absorbed from the power supply.
Safety module
With the help of the optional safety module, “STO” functionality acc. to EN ISO 13849 up to PLe/SIL3 can be easily realized without integrating additional contactors within the motor cable. This makes the structure of the safety circuit simpler and clearer. The potential danger emanating from the machine is reduced. The machine works reliably.
Cooling methods
Water
Air
Water
Write us a message, our sales experts will be happy to advise you.
Technical data for b maXX 4400
Type | Frame size | IN [A] | IMAX [A] | typ. motor rating [kW] | Overload factor | Dimensions WxHxD [mm] |
---|---|---|---|---|---|---|
BM 4412 | 1 S | 2.5 | 5 | 1.1 | 2 | 80 x 310 x 263 4) |
BM 4413 | 1 S | 4.5 | 9 | 2 | 2 | 80 x 310 x 263 4) |
BM 4412 | 1 B | 2.5 | 5 | 1.1 | 2 | 106 x 310 x 263 4) |
BM 4413 | 1 B | 4.5 | 9 | 2 | 2 | 106 x 310 x 263 4) |
BM 4422 | 2 | 7.5 | 15 | 3.4 | 2 | 106 x 428 x 340 / 320 |
BM 4423 | 2 | 11 | 22 | 5 | 2 | 106 x 428 x 340 / 320 |
BM 4424 | 2 | 15 | 30 | 6.8 | 2 | 106 x 428 x 340 / 320 |
BM 4425 | 2 | 15 | 40 2) | 6.8 | 2.6 | 106 x 428 x 340 / 320 |
BM 4426 3) | 2 | 22.5 | 45 2) | 6 | 2 | 106 x 428 x 340 / 320 |
BM 4426 | 2 | 22.5 | 45 2) | 10 | 2 | 106 x 428 x 340 / 320 |
BM 4432 | 3 | 22.5 | 45 | 10 | 2 | 155 x 510 x 340 / 325 |
BM 4433 | 3 | 30 | 60 | 13 | 2 | 155 x 510 x 340 / 325 |
BM 4434 | 3 | 45 | 90 | 20 | 2 | 155 x 510 x 340 / 325 |
BM 4435 | 3 | 60 | 90 | 28 | 1.5 | 155 x 510 x 340 / 325 |
BM 4443 | 4 | 80 | 120 | 36 | 1.5 | 190 x 624 x 374 / 327 |
BM 4444 | 4 | 100 | 130 | 45 | 1.3 | 190 x 624 x 374 / 327 |
BM 4445 | 4 | 130 | 170 | 58 | 1.3 | 190 x 624 x 374 / 327 |
BM 4446 | 4 | 150 | 200 | 75 | 1.3 | 190 x 624 x 374 / 327 |
BM 4453 | 5 | 150 | 195 | 75 | 1.3 | 307 x 656 x 374 / 321 |
BM 4454 | 5 | 210 | 260 | 110 | 1.3 | 307 x 656 x 374 / 321 |
BM 4462 | 6 | 250 | 325 | 132 | 1.3 | 437 x 815 x 378 / 316 |
BM 4463 | 6 | 300 | 390 | 160 | 1.3 | 437 x 815 x 378 / 316 |
BM 4466 | 6 | 350 | 450 | 175 | 1.3 | 437 x 815 x 378 / 316 |
BM 4472 | 7 | 450 | 585 | 225 | 1.3 | 520 x 600 x 340 5) |
BM 4473 | 7 | 615 | 780 | 315 | 1.3 | 520 x 600 x 340 5) |
Supply voltage: 207–528 V ± 0% AC
Supply frequency: 50/60 Hz
Rated supply voltage: 400 V
DC link voltage: 540 V rated voltage
Clock frequency: 2/4/8 kHz
Output voltage: 0–95% of the supply voltage
Electronic supply voltage: external 24 V DC (diagnostic capability)
Fan connection: Size 1–3: 24 V DC; Size 4–7: 230 V AC ± 10%
Certification: CE, CSA, UL
Height and depth without mounting brackets.
Depth of the air-cooled variants including the required bend radius of the connecting cables.
1) Depth of air cooling / depth of water cooling
2) for 1 second
3) single-phase
4) only air cooling available
5) only water cooling available
Subject to change without prior notice